From: Elmar.Brockmann@lt.admin.ch Message-ID: <5143BF97E6DDD1119F6F00805FC78025010955D2@mlts1.lt.admin.ch> To: igsmail@igscb.jpl.nasa.gov Subject: [IGSMAIL-3176]: Zimm with reduced coordinate repeatabilities for days 006 - 010 Date: Fri, 19 Jan 2001 10:58:55 +0100 Sender: owner-igsmail Precedence: bulk ****************************************************************************** IGS Electronic Mail 19 Jan 02:02:10 PST 2001 Message Number 3176 ****************************************************************************** Author: E. Brockmann Dear colleagues, For the global permanent site ZIMM we faced some problems during the data analysis from day 006 till day 010. The data are not totally corrupted, residuals and ambiguity resolution statics look normal, but the achieved coordinate repeatability is considerable reduced: 1 to 2 cm instead of millimeter level. No reason for this phenomenum was found, yet. The data since day 011 seem to be ok. Greetings Elmar Brockmann --------------------------------------------------------------------- Dr. Elmar Brockmann Swiss Federal Office of Topography (Bundesamt fuer Landestopographie) Section Satellite Geodesy (Abteilung Satelliten-Geodäsie) Seftigenstrasse 264 CH-3084 Wabern Switzerland Phone: ++41 / 31 / 963 22 56 Fax: ++41 / 31 / 963 24 59 Operator: ++41 / 31 / 963 21 11 Internet: Elmar.Brockmann@lt.admin.ch Web-Site: http://www.swisstopo.ch