Author: Tom Clark
Rob Sherwood <rshe @ nerc.ac.uk> and I have had a discussion about Z-18
Firmware and the overflow of Carrier Phase when GBSS is used to make the
RINEX files. I gave Rob the fix that Z-18 firmware release 6.5 fixed the
problem here at GODZ and Rob reported that most of the European Z-18s
are still running 6.4 (which has the overflow problem).
The problem shows up when the Hatanaka compressor fails after a few
weeks of operation when F14.x format numbers spill over to a length of
15 characters. A temporary fix is to cycle the receiver power (resetting
the cumulative phase counter), but the real fix seems to be to upload
the new firmware.
Since it appears that some Z-18 owners have not learned about the 6.4 =>
6.5 upgrade, I have made copies of the software available at URL
ftp://aleph.gsfc.nasa.gov/pub/z18/
In that directory you will find 2 files -- 18p_0065.dat is the binary
receiver image and upld.zip contains the Windoze-based binary file
uploader.
Thanks to Robert Snow and Bob Lemoine at Ashtech for providing this
firmware upgrade. Hope it helps you all.
Regards, Tom